According to China's "Classification of Combustion Performance of Building Materials and Products" (GB 8624-2012), Class A materials are non-combustible. The fire rating of backing board depends on the material:
- Class A backing board: gypsum board, glass magnesium board, rock wool board, etc., tested and certified as Class A1 (non-combustible) or Class A2 (low-smoke, non-combustible). For example, a certain brand of glass magnesium backing board tested as Class A1 (reference: National Fireproof Building Materials Quality Supervision and Inspection Center report).
- Non-Class A backing board: Ordinary density fiberboard and plywood are typically Class B2 (combustible) or Class B1 (difficult to burn), requiring the addition of flame retardants to improve the rating.